The DLT Series Molded Round FRP Cooling Tower is a modular cooling solution designed for consistent thermal performance and standardized industrial applications. Precision-molded FRP components ensure uniform quality, durability, and reliable operation across a wide range of cooling duties.
- Cooling tower
- Open Cooling Towers
FMT Counterflow FRP Cooling Tower
The FMT Series Counterflow FRP Cooling Tower combines high thermal efficiency with a compact footprint. It is designed for industrial and commercial applications requiring reliable cooling performance and efficient use of installation space.
(0) Reviews
Product Description
Key Advantages
Compact design
High thermal efficiency
Corrosion-resistant FRP structure
Energy-efficient fan system
Self-cleaning basin design
Reliable operation
Easy maintenance
Long service life
Typical Applications
Industrial cooling
HVAC systems
Chemical processing
Food production
Manufacturing
Pharmaceutical plants
Power support systems
Water treatment facilities
Working Principle
Warm water enters from the top while air is drawn upward through the tower. The counterflow arrangement maximizes contact between air and water, improving heat transfer efficiency and reducing tower footprint.
Customer Testimonials
“Compact footprint helped us solve serious space limitations.”
— Plant Engineer, Manufacturing Facility (India)
“Thermal efficiency is better than our previous system.”
— Operations Manager, Chemical Plant (UAE)
“Very stable operation even under continuous load.”
— Maintenance Supervisor, Pharmaceutical Plant (Saudi Arabia)
“Installation was quick and system started without issues.”
— Contractor, Industrial HVAC (Malaysia)
“Reduced operating costs compared to older cooling system.”
— Factory Manager, Food Processing (Brazil)
Product Parameters
| FMT Square cross flow FRP cooling tower parameter table | |||||||||||
| MODEL | WATER CAPACITY (m³/h) | L*W*H | POWER | BLADES Dia | Number of Blades | Volume | WEIGHT (kg) | ||||
| WB =28℃ | WB =27℃ | mm | mm | (mm) | (m³/h) | INLET/OUTLET DN | Blow/DRAIN DN | DEAD WEIGHT | RUNNING WEIGHT | ||
| FMT-50 | 40 | 50 | 1600*1600*2400 | 1.5 | 920 | 4 | 21000 | 80 | 32 | 460 | 1150 |
| FMT-50W | 40 | 50 | 1560*1560*2100 | 1.5 | 920 | 4 | 21000 | 100 | 20 | 355 | 507 |
| FMT-80 | 65 | 80 | 2250*2250*2775 | 3 | 1500 | 4 | 32300 | 100 | 32 | 560 | 1400 |
| FMT-80W | 65 | 80 | 2060*2060*2505 | 3 | 1500 | 4 | 32300 | 125 | 20 | 492 | 738 |
| FMT-100 | 80 | 100 | 2750*2750*2810 | 4 | 1800 | 4 | 61000 | 125 | 32 | 860 | 2150 |
| FMT-100W | 80 | 100 | 2560*2560*2540 | 4 | 1800 | 4 | 61000 | 150 | 20 | 744 | 1116 |
| FMT-150 | 130 | 150 | 4250*2250*2775 | 3.0*2 | 1500 | 4 | 64600 | 100*2 | 32 | 1000 | 2500 |
| FMT-150W | 130 | 150 | 4060*2060*2505 | 3.0*2 | 1500 | 4 | 64600 | 125*2 | 20 | 836 | 1254 |
| FMT-200 | 160 | 200 | 5250*2750*2810 | 4.0*2 | 1800 | 4 | 112000 | 125*2 | 32 | 1500 | 3750 |
| FMT-200W | 160 | 200 | 5060*2560*2540 | 4.0*2 | 1800 | 4 | 112000 | 150*2 | 20 | 1288 | 1932 |
| FMT-250 | 200 | 250 | 6250*2250*2775 | 3.0*3 | 1500 | 4 | 134300 | 100*3 | 32 | 2240 | 5600 |
| FMT-250W | 200 | 250 | 6060*2060*2505 | 3.0*3 | 1500 | 4 | 134300 | 125*3 | 20 | 1884 | 2826 |
| FMT-300 | 250 | 300 | 7750*2750*2810 | 4.0*3 | 1800 | 4 | 168000 | 125*3 | 32 | 2580 | 6450 |
| FMT-300W | 250 | 300 | 7560*2560*2540 | 4.0*3 | 1800 | 4 | 168000 | 150*3 | 20 | 2248 | 3372 |
| FMT-350 | 300 | 350 | 10250*2250*2775 | 4.0*4 | 1500 | 4 | 187000 | 100*4 | 32 | 2920 | 7550 |
| FMT-350W | 300 | 350 | 9060*2060*2505 | 4.0*4 | 1500 | 4 | 187000 | 125*4 | 20 | 2512 | 3680 |
| FMT-400 | 350 | 400 | 10250*2750*2810 | 4.0*4 | 1800 | 4 | 224000 | 125*4 | 32 | 3240 | 8100 |
| FMT-400W | 350 | 400 | 10060*2560*2540 | 4.0*4 | 1800 | 4 | 224000 | 150*4 | 20 | 2788 | 4182 |
| FMT-100 | 80 | 100 | 2750*2250*2810 | 4 | 2100 | 4 | 56000 | 125 | 32 | 500 | 2100 |
| FMT-100W | 80 | 100 | 2560*2060*2540 | 4 | 2100 | 4 | 56000 | 150 | 20 | 410 | 950 |
| FMT-150 | 125 | 150 | 3250*3250*2810 | 5.5 | 2100 | 4 | 92000 | 150 | 32 | 1100 | 2500 |
| FMT-150W | 125 | 150 | 3060*3060*2540 | 5.5 | 2100 | 4 | 92000 | 200 | 20 | 835 | 1200 |
| FMT-250 | 200 | 250 | 6250*2750*2810 | 4.0*2 | 1800*2 | 4 | 122000 | 125*2 | 32 | 2150 | 5950 |
| FMT-250W | 200 | 250 | 6060*2560*2540 | 4.0*2 | 1800*2 | 4 | 122000 | 150*2 | 20 | 1860 | 2580 |
| Design Conditions: | |||||||||||
| 1. Wet-bulb temp: 28°C; Inlet temp: 37°C; Outlet temp: 32°C; Cooling range: 5°C. | |||||||||||
| 2. Inlet pressure: 3-6m head (0.03-0.06MPa). Excessive pressure may damage the rotor, reduce cooling efficiency, and increase water drift. | |||||||||||
| 3. Model Code: F - Square, M - Modular, T - Cooling Tower, W - Without Basin. | |||||||||||
| Big temp. difference Square counterflow FRP Cooling Tower Parameter Table | ||||||||||||||||||
| Model | Selection parameter | Size mm | Fan(L-shape) | Pipe/mm | Weight | |||||||||||||
| WBT=28℃, waterflow (m³/h) | WBT=27℃, waterflow (m³/h) | L | Motor | Dia. | Air flow | INLET | OUTLET | Overflow | Drainage | Make-up | N.W | Operating weight | ||||||
| Δt=10℃ | Δt=20℃ | Δt=25℃ | Δt=10℃ | Δt=20℃ | Δt=25℃ | W | H | KW | mm | m³/h | mm | mm | mm | mm | mm | kg | kg | |
| KKN-200X | 60 | 50 | 48.1 | 61.5 | 53 | 52 | 2000 | 4000 | 3 | 1500 | 48000 | DN100 | DN100 | DN50 | DN50 | DN50 | 950 | 1970 |
| KKN-250X | 75 | 66.9 | 65.8 | 86.3 | 73.6 | 71.8 | 2250 | 4000 | 4 | 1800 | 60000 | DN100 | DN100 | DN50 | DN50 | DN50 | 1050 | 2150 |
| KKN-280X | 85 | 78 | 80 | 96 | 82.8 | 81.5 | 2500 | 4000 | 4 | 2000 | 75000 | DN125 | DN125 | DN50 | DN50 | DN50 | 1250 | 2585 |
| KKN-330X | 100 | 89.2 | 87.7 | 115 | 98.1 | 95.7 | 2750 | 4500 | 5.5 | 2000 | 90000 | DN125 | DN150 | DN50 | DN50 | DN50 | 1420 | 2900 |
| KKN-413X | 125 | 109.3 | 125 | 134.6 | 115.9 | 114.2 | 3000 | 4700 | 5.5 | 2400 | 105000 | DN125 | DN150 | DN80 | DN50 | DN50 | 1600 | 4290 |
| KKN-496X | 150 | 137.4 | 136.2 | 172.2 | 150.2 | 147.7 | 3250 | 4700 | 7.5 | 2400 | 120000 | DN150 | DN150 | DN80 | DN50 | DN50 | 1750 | 4515 |
| KKN-575X | 175 | 156 | 175 | 192 | 165.6 | 163.1 | 3500 | 4900 | 7.5 | 2800 | 150000 | DN150 | DN200 | DN80 | DN50 | DN50 | 2150 | 5285 |
| KKN-661X | 200 | 182.8 | 181.3 | 229.1 | 199.8 | 196.5 | 3750 | 5050 | 11 | 3000 | 180000 | DN200 | DN200 | DN80 | DN50 | DN50 | 2620 | 6050 |
| KKN-740X | 225 | 218.7 | 215 | 250 | 231.8 | 228.3 | 4000 | 5050 | 11 | 3000 | 210000 | DN200 | DN200 | DN80 | DN50 | DN50 | 2950 | 6590 |
| KKN-826X | 250 | 228.2 | 226.3 | 286 | 249.4 | 245.3 | 4500 | 5250 | 15 | 3400 | 240000 | DN200 | DN200 | DN80 | DN50 | DN50 | 3520 | 7850 |
| KKN-992X | 300 | 273.6 | 271.3 | 342.9 | 299.1 | 294.1 | 5000 | 5700 | 15 | 3400 | 300000 | DN250 | DN250 | DN80 | DN80 | DN50 | 4150 | 9180 |
| KKN-1300X | 400 | 364.4 | 361.4 | 456.7 | 398.3 | 391.8 | 5250 | 5900 | 18.5 | 3700 | 360000 | DN250 | DN250 | DN100 | DN80 | DN50 | 4680 | 10220 |
| KKN-1655X | 500 | 437.5 | 421.6 | 530 | 463.6 | 456.6 | 5500 | 5900 | 22 | 4200 | 420000 | DN200×2 | DN300 | DN100 | DN80 | DN50 | 5460 | 11380 |
| KKN-1985X | 600 | 500 | 480 | 615 | 530 | 522 | 6000 | 5900 | 30 | 4200 | 480000 | DN200×2 | DN300 | DN100 | DN80 | DN50 | 6520 | 13300 |
| KKN-2150X | 650 | 546 | 541.5 | 690 | 596.6 | 587.1 | 6500 | 6100 | 30 | 4700 | 540000 | DN200×2 | DN300 | DN100 | DN80 | DN50 | 7550 | 15270 |
| KKN-2315X | 700 | 638 | 632 | 770 | 662.2 | 650 | 7000 | 6100 | 30 | 4700 | 600000 | DN200×2 | DN300 | DN100 | DN80 | DN50 | 8200 | 16870 |
| Galvanized square steel counterflow | ||||||||||||||
| style | Water flow | Fan | size/mm | Pipe size/mm | Weight/kg | |||||||||
| 37-32/28 | Fan Dia. | Air volume | Power(KW) | L | W | H | Outlet | Overflow | Drainagee | Make up | N.W | Operating Weight | ||
| KKN-17G | 10 | 550 | 9500 | 0.37 | 930 | 930 | 2150 | DN50 | DN80 | DN50 | DN50 | DN25 | 245 | 430 |
| KKN-25G | 15 | 650 | 11000 | 0.55 | 930 | 1220 | 2450 | DN50 | DN80 | DN50 | DN50 | DN25 | 355 | 600 |
| KKN-35G | 20 | 750 | 13500 | 0.75 | 1220 | 1220 | 2450 | DN65 | DN80 | DN50 | DN50 | DN25 | 455 | 785 |
| KKN-50G | 30 | 800 | 17500 | 1.1 | 1220 | 1850 | 2950 | DN80 | DN80 | DN50 | DN50 | DN25 | 650 | 1150 |
| KKN-70G | 40 | 950 | 22500 | 1.5 | 1550 | 1850 | 2950 | DN80 | DN80 | DN50 | DN50 | DN25 | 785 | 1420 |
| KKN-85G | 50 | 1200 | 35000 | 1.5 | 1850 | 1850 | 3350 | DN100 | DN100 | DN50 | DN50 | DN25 | 900 | 1660 |
| KKN-108G | 65 | 1500 | 46000 | 2.2 | 1850 | 2500 | 3350 | DN100 | DN100 | DN50 | DN50 | DN50 | 1125 | 2150 |
| KKN-140G | 85 | 1500 | 56000 | 3 | 2500 | 2500 | 3350 | DN125 | DN125 | DN50 | DN50 | DN50 | 1460 | 2850 |
| KKN-165G | 100 | 1500 | 70000 | 3 | 2500 | 2800 | 3650 | DN125 | DN150 | DN50 | DN50 | DN50 | 1525 | 3100 |
| KKN-205G | 125 | 1800 | 88000 | 4 | 2500 | 2800 | 3650 | DN125 | DN150 | DN80 | DN50 | DN50 | 1650 | 3210 |
| KKN-250G | 150 | 2200 | 105000 | 5.5 | 2800 | 3000 | 3650 | DN150 | DN150 | DN80 | DN50 | DN50 | 1865 | 3600 |
| KKN-290G | 175 | 2200 | 123000 | 5.5 | 2800 | 3800 | 3650 | DN150 | DN200 | DN80 | DN50 | DN50 | 2130 | 4230 |
| KKN-330G | 200 | 2500 | 140000 | 7.5 | 3000 | 3800 | 3800 | DN200 | DN200 | DN80 | DN50 | DN50 | 2560 | 5150 |
| KKN-370G | 225 | 2500 | 160000 | 7.5 | 3500 | 3800 | 3800 | DN200 | DN200 | DN80 | DN50 | DN50 | 2960 | 5620 |
| KKN-415G | 250 | 3000 | 175000 | 11 | 3500 | 4000 | 3950 | DN200 | DN200 | DN80 | DN50 | DN50 | 3400 | 6525 |
| KKN-455G | 275 | 3000 | 195000 | 11 | 3500 | 4500 | 3950 | DN200 | DN250 | DN80 | DN80 | DN50 | 3635 | 7250 |
| KKN-500G | 300 | 3400 | 210000 | 11 | 3800 | 4800 | 4150 | DN250 | DN250 | DN80 | DN80 | DN50 | 3910 | 8126 |
| KKN-580G | 350 | 3400 | 245000 | 11 | 4200 | 4800 | 4150 | DN250 | DN250 | DN100 | DN80 | DN50 | 4015 | 8229 |
| KKN-660G | 400 | 3400 | 280000 | 15 | 4800 | 4800 | 4150 | DN250 | DN250 | DN100 | DN80 | DN50 | 4350 | 8950 |
| KKN-745G | 450 | 3600 | 315000 | 15 | 5100 | 5100 | 4150 | DN250 | DN250 | DN100 | DN80 | DN50 | 4680 | 9880 |
| KKN-830G | 500 | 3600 | 350000 | 18.5 | 5500 | 5500 | 4450 | DN200×2 | DN300 | DN100 | DN80 | DN50 | 5150 | 11200 |
| KKN-995G | 600 | 3600 | 420000 | 18.5 | 6000 | 6000 | 4450 | DN200×2 | DN300 | DN100 | DN80 | DN50 | 5680 | 12850 |
| KKN-1150G | 700 | 4200 | 490000 | 22 | 6400 | 6400 | 4450 | DN200×2 | DN300 | DN100 | DN80 | DN50 | 6050 | 14250 |
| KKN-1325G | 800 | 4200 | 560000 | 22 | 6800 | 6800 | 4650 | DN250×2 | DN350 | DN100 | DN80 | DN50 | 6550 | 15800 |
| KKN-1490G | 900 | 4700 | 630000 | 30 | 7200 | 7200 | 4650 | DN250×2 | DN350 | DN100 | DN80 | DN50 | 6950 | 17300 |
| KKN-1650G | 1000 | 4700 | 680000 | 30 | 7600 | 7600 | 4650 | DN250×2 | DN350 | DN100 | DN80 | DN50 | 7450 | 19000 |
FAQ
-
Q1: Why is a counterflow design more thermally efficient?
In a counterflow configuration, air travels upward directly against the downward flow of water, maximizing temperature differential throughout the heat exchange process. This generally results in higher cooling efficiency and a more compact tower footprint.
-
Q2: How does the FMT Series help save installation space?
Because of its higher thermal efficiency, the FMT Series can often achieve the required cooling duty with a smaller footprint than comparable crossflow designs, making it ideal for projects with limited installation space.
-
Q3: Can the tower operate under varying load conditions?
Yes. The tower is designed to maintain stable performance across a wide operating range and can be equipped with variable frequency drives (VFDs) for improved energy efficiency under partial-load operation.
-
Q4: What maintenance practices are recommended?
Regular inspection of the fan system, water distribution nozzles, fill media, and basin is recommended. Proper water treatment will further extend component life and maintain thermal performance.
-
Q5: What industries commonly use the FMT Series?
The FMT Series is widely applied in manufacturing, chemical processing, food production, pharmaceuticals, HVAC systems, and water treatment facilities where high cooling efficiency and compact design are important.
Review
Write A Review
Inquiry Now
Related Products
The KKH Series Crossflow Cooling Tower utilizes a crossflow heat exchange design that combines low noise operation, reduced pumping requirements, and easy maintenance access. It is particularly suitable for commercial and urban cooling applications.
The FMT Series Counterflow FRP Cooling Tower combines high thermal efficiency with a compact footprint. It is designed for industrial and commercial applications requiring reliable cooling performance and efficient use of installation space.
The XWKKBL Series Plume Abatement Cooling Tower is designed to reduce visible plume emissions during cold-weather operation while maintaining efficient cooling performance and water conservation.