Faq

  • Q5: Does it require compressed air?

    A:No, just 380V three-phase power.


  • Q1: What is the difference between manual and fully automatic models?

    A:Manual requires operator positioning of hammers; automatic self-adjusts. Manual offers better cost performance.


  • Q2:What is the difference between KLQ-Z and KLQ-D series?

    A:KLQ-Z has higher frequency (195Hz). KLQ-D has stronger excitation force (up to 2540N) and wider adjustment range (280mm).


  • Q3. What air pressure is required?

    A:KLQ-Z series: 0.5-0.7Mpa. KLQ-D series: 0.6-0.8Mpa.


  • Q4. How to choose the number of hammers?

    A:2-3 hammers for small/medium furnaces. 4-5 hammers for large furnaces.