Q5: Does it require compressed air?
A:No, just 380V three-phase power.
-
Q1: What is the difference between manual and fully automatic models?
A:Manual requires operator positioning of hammers; automatic self-adjusts. Manual offers better cost performance.
-
Q2:What is the difference between KLQ-Z and KLQ-D series?
A:KLQ-Z has higher frequency (195Hz). KLQ-D has stronger excitation force (up to 2540N) and wider adjustment range (280mm).
-
Q3. What air pressure is required?
A:KLQ-Z series: 0.5-0.7Mpa. KLQ-D series: 0.6-0.8Mpa.
-
Q4. How to choose the number of hammers?
A:2-3 hammers for small/medium furnaces. 4-5 hammers for large furnaces.